When installing a Gladore water
cleaning device, we suggest you use professional installers who have knowledge
of water and electricity in order to avoid damage and injury. If you want to do
by yourself, you must consult the installation book, prepare the installation
tools, and proceed exactly according to provided steps. If you come across any
problems, please contact our after-sales department or local Gladore agent.
In order to insure safe usage and guarantee purified water,
our engineers strongly suggest you debug the machine after installation and
before usage. Please refer to the following debugging points:
- Open plating ball valve and plastic ball valve, close back
flush valve, insert transformer plug.
- Press back flush ball valve at the time the machine begins
to produce purified water in order to see whether waste water ejecting out of
the machine. If it is, the machine is working properly
- Debug automatic startup and stop: close the water-stored
pressure barrel ball valve. The high pressure pump will stop working. Open the
water faucet and the high pressure pump will operate by itself. Repeat
debugging. After the machine comes back into gear, open the water-stored
pressure barrel ball valve.
- Debugging the low pressure switch: close plating ball
valve; set the state of lack water. The work of the low pressure switch will
cease. The work of the high pressure pump will continue automatically. After it
comes into gear, open the ball valve.
- Check if the waste water is in normal condition and
whether there is leakage in the linking parts and pipes. Afterwards, stop the
high pressure pump and stop using water. Check if there is waste water coming
out. If this happens, you need to change the electromagnetic valve or check valve.
- Checking the water quality and postposition active carbon:
After finishing installation and debugging, let the machine operate for one to
two buckets of water, let the postposition active carbon dissolve in the water
and flow out with it.
- After the installation and debugging, the water purifier
can be put into normal use. The whole system of Gladore F-series water purifiers is
automatically controlled. If there is no water supply, the system will
automatically stop. If the water tank is full of pure water, the system will
automatically stop. Now, you can freely enjoy pure water.